# Hallway width: code minimum, house hallways and wheelchair widths

The International Residential Code asks for hallways at least 3 ft (36 in, 91 cm) wide in a house, with a ceiling at least 7 ft (2.13 m) high.

A 36 in hallway lets a wheelchair roll along it and turn into a door with 32 in of clear opening. For a U-turn around a wall, the ADA Standards ask for 42 in (107 cm) on the way in and 48 in (122 cm) at the turn, and a wheelchair needs 60 in (152 cm) to turn around or to pass another.

## Minimum hallway width by code

-   **United States, houses.** The International Residential Code (section R311.6 in the 2021 edition, R318 in 2024) asks that a hallway is at least 3 ft (91 cm) wide. Section R305 asks for a hallway ceiling at least 7 ft (2.13 m) high. States and towns can change both.
-   **United States, apartments.** In multifamily buildings covered by the Fair Housing Act, HUD asks for an accessible route of at least 36 in (91 cm) through each covered unit, and prefers wider halls, especially long ones.
-   **Public buildings.** The 2010 ADA Standards ask for a clear width of 36 in (91 cm) along an accessible route, or 32 in (81 cm) for no more than 24 in (61 cm) of length, such as at a doorway.
-   **England.** Approved Document M asks that a new home's hallways are at least 900 mm wide, and 1050 or 1200 mm where you turn from the hallway into a door with only 775 or 750 mm of clear opening. A radiator or other short obstruction may narrow a hallway to 750 mm for up to 2 m.

## Hallway widths and what they allow

| Width | Metric | What it allows |
| --- | --- | --- |
| 36 in | 91 cm | The US code minimum. A wheelchair rolls straight along and turns 90° into a door with 32 in clear. |
| 42 in | 107 cm | The ADA width on the way into and out of a U-turn around a wall less than 48 in wide. |
| 48 in | 122 cm | The ADA width at such a U-turn. |
| 60 in | 152 cm | A wheelchair turns around in a 60 in circle, and two wheelchairs pass each other. |

Measure the width between the finished walls. Drywall, baseboards and handrails all take some of the framed width.

## Hallway width in a house

1.  Start from 36 in (91 cm), the code minimum, for a short hall with few doors.
2.  Make a long hall wider. HUD prefers wider halls, especially long ones, because they are easier to use and wheelchair footrests knock the walls and door frames less.
3.  Plan 60 in (152 cm) where a wheelchair needs to turn around, such as at the end of a hall. Where two 36 in halls meet in a T, a wheelchair can turn if the T fits in a 60 in square.
4.  Keep the ceiling at least 7 ft (2.13 m) high. In a basement, beams and ducts may come down to 6 ft 4 in (1.93 m).

For doors along the hall, see [door sizes](https://simplehouseplanner.com/guides/door-sizes/), and for a home planned around a wheelchair, see [wheelchair accessible home dimensions](https://simplehouseplanner.com/guides/wheelchair-accessible-home-dimensions/).

## Hallway width for a wheelchair

The ADA Standards cover public buildings, not private houses, but their sizes show what a wheelchair needs:

-   **Straight hall:** at least 36 in (91 cm), and 32 in (81 cm) for no more than 24 in (61 cm), separated by stretches at least 48 in (122 cm) long.
-   **U-turn around a wall less than 48 in wide:** 42 in (107 cm) before and after the turn and 48 in (122 cm) at it, or 60 in (152 cm) at the turn.
-   **Turning around:** a 60 in (152 cm) circle, or a T-shape inside a 60 in square with arms 36 in (91 cm) wide.
-   **Passing:** a hall narrower than 60 in needs a passing space of 60 × 60 in (152 × 152 cm) at least every 200 ft (61 m).

   ![A furnished two-bedroom apartment with named rooms and their areas, beside the furniture library.](https://simplehouseplanner.com/screenshots/rooms-light.webp)

Hallways and rooms drawn to scale in Simple House Planner, with each room's area shown.

## Check your hallway to scale

Draw the walls, add doors and measure the hallway between them to see where it needs to be wider. Free, in your browser, with no account.

[Open editor](https://simplehouseplanner.com/app/) [Edit with ChatGPT](https://simplehouseplanner.com/chatgpt/)

## Questions

### What is the minimum hallway width by code?

3 ft (36 in, 91 cm) under the International Residential Code. Check your local code, because states and towns can change it.

### What is the standard hallway width in a house?

The code minimum of 36 in (91 cm) is the starting point. Wider halls are easier to use, and HUD prefers them for long halls; 42 in (107 cm) also meets the ADA width for the approach to a U-turn.

### How wide should a hallway be for a wheelchair?

At least 36 in (91 cm) to roll through, 42 to 48 in (107 to 122 cm) at a U-turn, and 60 in (152 cm) to turn around or let two wheelchairs pass.

### Is 3 feet wide enough for a hallway?

It meets the code, and a wheelchair can roll through it and turn into a door with 32 in clear. Two wheelchairs need 60 in (152 cm) to pass.

### What is the ADA hallway width?

36 in (91 cm), with short stretches of 32 in (81 cm) allowed for up to 24 in. Halls narrower than 60 in need a 60 × 60 in passing space every 200 ft.

### How high must a hallway ceiling be?

At least 7 ft (2.13 m) under the International Residential Code, the same as for living rooms and bedrooms.

## Sources

-   [City of Richmond, Kentucky: IRC section R311, means of egress (R311.6 hallways)](https://cms2.revize.com/revize/richmondky/Means%20of%20Egress.pdf)
-   [City of Boise: IRC code handout 434, ceiling height (R305)](https://www.cityofboise.org/media/3924/434-irc-code-section-r305-ceiling-height.pdf)
-   [International Code Council: 2024 IRC Code and Commentary, chapter 3 sample (section numbers of the 2024 edition)](https://shop.iccsafe.org/media/wysiwyg/material/3110S241-Sample.pdf)
-   [HUD: Fair Housing Act Design Manual, chapter 4, accessible route into and through the unit](https://www.huduser.gov/portal/sites/default/files/publications/pdf/fairhousing/fairch4.pdf)
-   [US Access Board: 2010 ADA Standards for Accessible Design, sections 304 and 403](https://www.access-board.gov/ada/)
-   [UK government: Approved Document M, volume 1, dwellings](https://www.gov.uk/government/publications/access-to-and-use-of-buildings-approved-document-m)

## Doors, windows and stairs

-   [Door sizes](https://simplehouseplanner.com/guides/door-sizes/)
    
    A standard door is 80 in (6 ft 8 in) tall. Interior doors are 24 to 36 in wide and front doors 36 in. Door size chart, rough openings and code minimums.
    
-   [Garage door sizes](https://simplehouseplanner.com/guides/garage-door-sizes/)
    
    A single garage door is 8 or 9 ft wide and 7 or 8 ft tall. A double door is 16 ft wide. Sizes in feet and meters, and the headroom and side room you need.
    
-   [Window sizes](https://simplehouseplanner.com/guides/window-sizes/)
    
    Window sizes are written width then height: a 3050 window is 36 × 60 in. Size chart in inches and cm, rough openings and the window size for a bedroom.
    
-   [Egress window size](https://simplehouseplanner.com/guides/egress-window-size/)
    
    An egress window must open 5.7 sq ft, at least 24 in high and 20 in wide, with its sill at most 44 in above the floor. Window wells, examples and exceptions.
    
-   [Wheelchair access](https://simplehouseplanner.com/guides/wheelchair-accessible-home-dimensions/)
    
    ADA sizes for an accessible home: doors with 32 in (81 cm) clear width, a 60 in (152 cm) turning space, 36 in (91 cm) routes and ramps no steeper than 1:12.
    
-   [Stair dimensions](https://simplehouseplanner.com/guides/stair-dimensions/)
    
    Code stairs: risers up to 7 3/4 in, treads at least 10 in, 36 in wide, 6 ft 8 in headroom. Risers and treads for 8, 9 and 10 ft ceilings, with the sums.
    
-   [Spiral stairs](https://simplehouseplanner.com/guides/spiral-staircase-dimensions/)
    
    A code spiral stair needs 26 in of clear width, about a 5 ft diameter, risers up to 9 1/2 in and 6 ft 6 in headroom. Diameters, floor openings and treads.
    
-   [Ceiling height](https://simplehouseplanner.com/guides/ceiling-height/)
    
    US homes usually have 8 or 9 ft ceilings. The code minimum is 7 ft for living space and 6 ft 8 in for bathrooms; basement beams may drop to 6 ft 4 in.
    

[Guides](https://simplehouseplanner.com/guides/)

Checked on 15 November 2026. Codes change and differ between countries, states and towns. Ask your local building department before you build.