Wheelchair accessible home dimensions: doors, turning space, ramps and bathrooms

The 2010 ADA Standards ask for doors with at least 32 in (81 cm) of clear width, a turning space 60 in (152 cm) across, routes and halls at least 36 in (91 cm) wide, and ramps no steeper than 1:12, which is 1 in of rise for every 12 in of length.

The ADA applies to public places, businesses and government buildings, not to the private part of a home. Many people use its sizes by choice when they plan a home for a wheelchair user or for aging in place.

Who has to follow these sizes

Door width for a wheelchair

A door needs at least 32 in (81 cm) of clear width. Measure it with the door open at 90°, from the face of the door to the stop on the other side. The open door and the stop take up part of the frame, so a 32 in door leaf gives less than 32 in clear. Plan a wider leaf, such as 36 in (91 cm).

Approach from the frontDepth in front of the doorWidth beyond the latch
Pull side60 in (152 cm)18 in (46 cm)
Push side48 in (122 cm)0 in, or 12 in (30 cm) if the door has a closer and a latch

Wheelchair turning space

A turning space is either a circle 60 in (152 cm) across, or a T-shaped space inside a 60 in square with arms and base 36 in (91 cm) wide. It may reach under a sink or a counter where there is knee and toe space, and doors may swing into it. A wheelchair at rest needs a clear floor space of 30 × 48 in (76 × 122 cm).

In homes built to the ADA Standards, every room on the accessible route has a turning space.

60 in Circle 60 in across 36 in 36 in T-shape in a 60 in square
The two turning spaces in the ADA Standards. Either one works.

Hallway width

A route or hallway is at least 36 in (91 cm) wide. It may narrow to 32 in (81 cm) for up to 24 in (61 cm) of length, for example past a door frame, if the parts between are 36 in wide and at least 48 in (122 cm) long. Where the route makes a U-turn around a wall less than 48 in wide, it needs 42 in (107 cm) before and after the turn and 48 in (122 cm) at the turn, unless the turn is 60 in (152 cm) wide. See also hallway width.

Ramp width and slope

RiseRamp length at 1:12Handrails
6 in (15 cm)6 ft (1.8 m)Not required
12 in (30 cm)12 ft (3.7 m)Both sides
18 in (46 cm)18 ft (5.5 m)Both sides
24 in (61 cm)24 ft (7.3 m)Both sides
30 in (76 cm)30 ft (9.1 m)Both sides; the longest single run

The lengths do not include landings. A front door 36 in (91 cm) above the ground needs 36 ft (11 m) of ramp in two runs, plus a landing of at least 60 in (152 cm) between them and one at each end. Work out the runs, landings and floor space for your own rise with the ramp calculator.

Accessible bathroom dimensions

ElementADA size
Turning space in the room60 in (152 cm) circle or T-shape
Toilet center to side wall16 to 18 in (41 to 46 cm)
Clear space at the toilet60 in (152 cm) wide × 56 in (142 cm) deep
Toilet seat height17 to 19 in (43 to 48 cm); 15 to 19 in (38 to 48 cm) in dwelling units
Grab bars33 to 36 in (84 to 91 cm) high; side bar 42 in (107 cm), rear bar 36 in (91 cm) long
SinkRim no higher than 34 in (86 cm); knee space 27 in (69 cm) high and 30 in (76 cm) wide
Roll-in shower30 × 60 in (76 × 152 cm) inside, 60 in (152 cm) wide entry
Transfer shower36 × 36 in (91 × 91 cm) inside
Bathtub30 in (76 cm) of clear floor along its length
Mirror over the sinkBottom edge no higher than 40 in (102 cm)

The door may not swing into the clear space of any fixture. In a single-user bathroom it may, if a 30 × 48 in (76 × 122 cm) clear space is left beyond the door's swing. In dwelling units, grab bars can wait if the walls are reinforced for them, and a cabinet may stand under the sink if it can be removed. Details are in toilet clearance, shower size and vanity dimensions.

Kitchen and reach

Wheelchair user homes in England

England's Approved Document M sets the sizes for a wheelchair user dwelling (category M4(3)), which applies where the planning permission asks for it. Halls are at least 1,050 mm (41 in) wide, or 1,200 mm (47 in) where you approach a door from the side. Doors have a clear opening of at least 850 mm (33.5 in). The entrance area and the bathroom each have a clear turning circle of 1,500 mm (59 in).

Questions

What door width is needed for a wheelchair?

At least 32 in (81 cm) of clear width under the ADA Standards, measured with the door open at 90°. That needs a door leaf wider than 32 in, such as 36 in (91 cm).

What is the ADA door width?

32 in (81 cm) of clear opening at minimum, and 36 in (91 cm) where the doorway is more than 24 in (61 cm) deep.

How much space does a wheelchair need to turn around?

A circle 60 in (152 cm) across, or a T-shaped space inside a 60 in square with arms and base 36 in (91 cm) wide.

How wide should a wheelchair ramp be?

At least 36 in (91 cm) between the handrails, with handrails on both sides when the ramp rises more than 6 in (15 cm).

What is the maximum slope of a wheelchair ramp?

1:12, or 1 ft of ramp for each inch of rise, with no more than 30 in (76 cm) of rise in one run before a level landing.

Does the ADA apply to private homes?

No, except for any part used for a business open to clients. The Fair Housing Act sets accessibility rules for many apartment buildings with 4 or more units first occupied after 13 March 1991.