Wheelchair accessible home dimensions: doors, turning space, ramps and bathrooms
The 2010 ADA Standards ask for doors with at least 32 in (81 cm) of clear width, a turning space 60 in (152 cm) across, routes and halls at least 36 in (91 cm) wide, and ramps no steeper than 1:12, which is 1 in of rise for every 12 in of length.
The ADA applies to public places, businesses and government buildings, not to the private part of a home. Many people use its sizes by choice when they plan a home for a wheelchair user or for aging in place.
Who has to follow these sizes
- ADA. The 2010 Standards cover state and local government buildings, public accommodations such as shops and hotels, and commercial facilities. In a home, they cover only the part used for a business that clients or employees visit, with its entrance and restroom.
- Fair Housing Act. Apartment buildings with 4 or more units and an elevator, and ground-floor units in other buildings with 4 or more units, first occupied after 13 March 1991, must have doors wide enough for wheelchairs, an accessible route through each unit, controls within reach, walls reinforced for grab bars, and kitchens and bathrooms a wheelchair can move in.
- Houses. For a private house, these sizes are a choice. Your state or city may have its own accessibility rules.
Door width for a wheelchair
A door needs at least 32 in (81 cm) of clear width. Measure it with the door open at 90°, from the face of the door to the stop on the other side. The open door and the stop take up part of the frame, so a 32 in door leaf gives less than 32 in clear. Plan a wider leaf, such as 36 in (91 cm).
- A doorway deeper than 24 in (61 cm), such as a short passage, needs 36 in (91 cm) clear.
- A threshold is no higher than ½ in (13 mm).
- Leave level floor on both sides of the door to open it from a wheelchair, as in the table.
| Approach from the front | Depth in front of the door | Width beyond the latch |
|---|---|---|
| Pull side | 60 in (152 cm) | 18 in (46 cm) |
| Push side | 48 in (122 cm) | 0 in, or 12 in (30 cm) if the door has a closer and a latch |
Wheelchair turning space
A turning space is either a circle 60 in (152 cm) across, or a T-shaped space inside a 60 in square with arms and base 36 in (91 cm) wide. It may reach under a sink or a counter where there is knee and toe space, and doors may swing into it. A wheelchair at rest needs a clear floor space of 30 × 48 in (76 × 122 cm).
In homes built to the ADA Standards, every room on the accessible route has a turning space.
Hallway width
A route or hallway is at least 36 in (91 cm) wide. It may narrow to 32 in (81 cm) for up to 24 in (61 cm) of length, for example past a door frame, if the parts between are 36 in wide and at least 48 in (122 cm) long. Where the route makes a U-turn around a wall less than 48 in wide, it needs 42 in (107 cm) before and after the turn and 48 in (122 cm) at the turn, unless the turn is 60 in (152 cm) wide. See also hallway width.
Ramp width and slope
- The slope is no steeper than 1:12 (8.3%), so each inch of rise needs 1 ft of ramp. The slope across the ramp is no steeper than 1:48.
- The ramp is at least 36 in (91 cm) wide, measured between the handrails.
- One run rises no more than 30 in (76 cm). Each run has a level landing at the top and the bottom, at least 60 in (152 cm) long and as wide as the ramp. Where the ramp turns, the landing is at least 60 × 60 in (152 × 152 cm).
- A run that rises more than 6 in (15 cm) has handrails on both sides, 34 to 38 in (86 to 97 cm) above the ramp.
- In existing buildings with no room for a longer ramp, a slope up to 1:10 is allowed for a rise of 6 in or less, and up to 1:8 for a rise of 3 in (8 cm) or less.
| Rise | Ramp length at 1:12 | Handrails |
|---|---|---|
| 6 in (15 cm) | 6 ft (1.8 m) | Not required |
| 12 in (30 cm) | 12 ft (3.7 m) | Both sides |
| 18 in (46 cm) | 18 ft (5.5 m) | Both sides |
| 24 in (61 cm) | 24 ft (7.3 m) | Both sides |
| 30 in (76 cm) | 30 ft (9.1 m) | Both sides; the longest single run |
The lengths do not include landings. A front door 36 in (91 cm) above the ground needs 36 ft (11 m) of ramp in two runs, plus a landing of at least 60 in (152 cm) between them and one at each end. Work out the runs, landings and floor space for your own rise with the ramp calculator.
Accessible bathroom dimensions
| Element | ADA size |
|---|---|
| Turning space in the room | 60 in (152 cm) circle or T-shape |
| Toilet center to side wall | 16 to 18 in (41 to 46 cm) |
| Clear space at the toilet | 60 in (152 cm) wide × 56 in (142 cm) deep |
| Toilet seat height | 17 to 19 in (43 to 48 cm); 15 to 19 in (38 to 48 cm) in dwelling units |
| Grab bars | 33 to 36 in (84 to 91 cm) high; side bar 42 in (107 cm), rear bar 36 in (91 cm) long |
| Sink | Rim no higher than 34 in (86 cm); knee space 27 in (69 cm) high and 30 in (76 cm) wide |
| Roll-in shower | 30 × 60 in (76 × 152 cm) inside, 60 in (152 cm) wide entry |
| Transfer shower | 36 × 36 in (91 × 91 cm) inside |
| Bathtub | 30 in (76 cm) of clear floor along its length |
| Mirror over the sink | Bottom edge no higher than 40 in (102 cm) |
The door may not swing into the clear space of any fixture. In a single-user bathroom it may, if a 30 × 48 in (76 × 122 cm) clear space is left beyond the door's swing. In dwelling units, grab bars can wait if the walls are reinforced for them, and a cabinet may stand under the sink if it can be removed. Details are in toilet clearance, shower size and vanity dimensions.
Kitchen and reach
- A kitchen with counters on two opposite sides has at least 40 in (102 cm) between them and two entries. A U-shaped kitchen has at least 60 in (152 cm) between opposite counters.
- In an accessible dwelling unit, at least one section of counter 30 in (76 cm) wide is no higher than 34 in (86 cm), with knee space below.
- Switches, outlets and controls are 15 to 48 in (38 to 122 cm) above the floor, where nothing is in the way of the reach.
Wheelchair user homes in England
England's Approved Document M sets the sizes for a wheelchair user dwelling (category M4(3)), which applies where the planning permission asks for it. Halls are at least 1,050 mm (41 in) wide, or 1,200 mm (47 in) where you approach a door from the side. Doors have a clear opening of at least 850 mm (33.5 in). The entrance area and the bathroom each have a clear turning circle of 1,500 mm (59 in).
Questions
What door width is needed for a wheelchair?
At least 32 in (81 cm) of clear width under the ADA Standards, measured with the door open at 90°. That needs a door leaf wider than 32 in, such as 36 in (91 cm).
What is the ADA door width?
32 in (81 cm) of clear opening at minimum, and 36 in (91 cm) where the doorway is more than 24 in (61 cm) deep.
How much space does a wheelchair need to turn around?
A circle 60 in (152 cm) across, or a T-shaped space inside a 60 in square with arms and base 36 in (91 cm) wide.
How wide should a wheelchair ramp be?
At least 36 in (91 cm) between the handrails, with handrails on both sides when the ramp rises more than 6 in (15 cm).
What is the maximum slope of a wheelchair ramp?
1:12, or 1 ft of ramp for each inch of rise, with no more than 30 in (76 cm) of rise in one run before a level landing.
Does the ADA apply to private homes?
No, except for any part used for a business open to clients. The Fair Housing Act sets accessibility rules for many apartment buildings with 4 or more units first occupied after 13 March 1991.
Sources
- U.S. Access Board: ADA Accessibility Standards, with 28 CFR 36.401 and sections 304, 305, 403 to 405, 505, 603 to 610, 804 and 809
- U.S. Access Board: Guide to the ADA Standards, entrances, doors and gates
- Legal Information Institute: 24 CFR 100.205, design and construction requirements of the Fair Housing Act
- Legal Information Institute: 24 CFR 100.201, definition of covered multifamily dwellings
- UK government: Approved Document M, volume 1, dwellings
Checked on 15 November 2026. Codes change and differ between countries, states and towns. Ask your local building department before you build.