Ramp calculator
Enter the height the ramp climbs and choose a rule. The calculator finds the shortest ramp that the rule allows, splits it into runs with level landings, and gives the floor space it needs.
How the calculator works
- Slope. The steepest slope the rule allows, unless you set one under More options. In England, the steepest slope depends on the length of the run: 1:12 up to 2 m, then 1 in (10 + the length in meters), down to 1:20 at 10 m. In Spain it is 10% for a run under 3 m, 8% under 6 m and 6% for longer runs.
- Runs. The height is split into equal runs, so that no run rises or reaches further than the rule allows: 30 in under the ADA, 500 mm in England, a 6 m run under DIN 18040 and 9 m in Spain. Where shorter runs may be steeper, the calculator tries every number of runs and keeps the shortest ramp, landings included.
- Landings. A level landing at the bottom, at the top and between runs, as long as the rule asks.
- Floor space. A straight ramp is as long as its runs and landings together. A switchback puts the runs side by side and turns on a landing at each end: one run plus the landings long, and as wide as all runs together. Add the space for the railings between the runs.
Worked example
A front door is 36 in (91 cm) above the ground. The ramp follows the 2010 ADA Standards.
| Step | Calculation | Result |
|---|---|---|
| Ramp length | 36 in × 12 at 1:12 | 36 ft (10.97 m) |
| Runs | 36 in ÷ 30 in = 1.2, rounded up | 2 runs of 18 ft (5.49 m), each rising 18 in (46 cm) |
| Landings | One between the runs, one at the top, one at the bottom | 3 × 5 ft (1.52 m) |
| Straight | 5 + 18 + 5 + 18 + 5 ft | 51 ft × 3 ft (15.54 × 0.91 m) |
| Switchback | 18 ft run + 5 ft landing at each end; 2 × 36 in wide | 28 ft × 6 ft (8.53 × 1.83 m) |
In England the shortest ramp is not always the gentlest. For 500 mm of rise at a home, two runs of 3.33 m at 1:13.3 with landings of 1.2 m take 10.27 m in all. One run of 10 m at 1:20 with its two landings takes 12.4 m.
Ramp rules by country
The calculator checks the rule you choose. All are rules for ramps that wheelchair users can use.
| Rule | Steepest slope | Longest run | Landings | Width |
|---|---|---|---|---|
| United States, 2010 ADA Standards | 1:12 (8.33%) | 30 in (760 mm) of rise | 60 in (1525 mm) long; 60 × 60 in where the ramp turns | 36 in (915 mm) |
| England, Approved Document M, homes (M4(2)) | 1:12 for a 2 m run to 1:20 for 10 m | 10 m, 500 mm of rise | 1200 mm long | 900 mm; 1200 mm on a shared approach |
| England, Approved Document M, other buildings | 1:12 for a 2 m run to 1:20 for 10 m | 10 m, 500 mm of rise; 2 m of total rise | 1.2 m at top and bottom, 1.5 m between runs | 1.5 m |
| Germany, DIN 18040 | 6% | 6 m | 150 cm between runs; 150 × 150 cm at top and bottom | 120 cm |
| Spain, CTE, accessible route | 10% under 3 m, 8% under 6 m, then 6% | 9 m | 1.50 m between runs; 1.20 m level at both ends | 1.20 m |
- Handrails. The ADA asks for handrails on both sides of a run that rises more than 6 in (150 mm), 34 to 38 in (865 to 965 mm) high. Approved Document M asks for a handrail on both sides of a ramp in buildings other than homes. DIN 18040 asks for handrails on both sides, 85 to 90 cm high, and wheel guards 10 cm high. The CTE asks for handrails on both sides of a ramp of 6% or more that rises more than 18.5 cm.
- Gentle slopes. Under the ADA, a path no steeper than 1:20 is a walking surface, not a ramp.
- Existing buildings. Where there is no room, the ADA allows a slope up to 1:10 for a rise of 6 in (150 mm) or less, and up to 1:8 for 3 in (75 mm) or less. Enter the slope under More options to see the length; the check still marks it, because it applies the rule for new ramps.
- Homes in England. The calculator uses M4(2), accessible and adaptable dwellings. The basic level M4(1) allows runs up to 10 m at 1:15 and up to 5 m at 1:12, with landings 1200 mm long.
For doors, turning space and bathrooms, see wheelchair accessible home dimensions.
Questions
How long does a wheelchair ramp need to be?
Under the ADA, 1 ft of ramp for each inch of rise: a 24 in rise needs 24 ft of ramp, plus a landing of at least 5 ft (1.52 m) at the top and at the bottom.
How do you calculate the slope of a ramp?
Divide the rise by the level length. 2 ft of rise over 24 ft is 1:12, which is 8.3% (rise ÷ length × 100) or 4.8° (the arctangent of rise ÷ length).
How many landings does a ramp need?
One at the top and one at the bottom of every run. Under the ADA, one run rises at most 30 in (760 mm), so a 36 in rise needs two runs and three landings.
What is the maximum ramp gradient in the UK?
Approved Document M allows 1:12 for a run of 2 m, 1:15 for 5 m and 1:20 for 10 m, and values in between, such as 1:14 for 4 m. No run may rise more than 500 mm.
How steep can a ramp be in Germany?
DIN 18040 allows 6%, with no cross slope, and a landing at least 150 cm long after each run of 6 m.
Can a ramp be steeper than 1:12?
For new ramps under the ADA, no. In existing buildings without room, 1:10 is allowed for a rise of 6 in or less and 1:8 for 3 in or less.
Sources
- U.S. Access Board: 2010 ADA Standards, 405 Ramps, 403.3 and 505 Handrails
- UK government: Approved Document M, Volume 1, Dwellings, paragraphs 1.7 and 2.10 and Diagram 2.1 (PDF)
- UK government: Approved Document M, Volume 2, Buildings other than dwellings, paragraph 1.26 and Table 1 (PDF)
- DGUV: Barrierefreie Arbeitsgestaltung, Kapitel 4.3 Rampen, after DIN 18040-1 (German, PDF)
- nullbarriere.de: DIN 18040-2 Rampen (German)
- Código Técnico de la Edificación: DB-SUA, SUA 1, section 4.3 Rampas (Spanish, PDF)
Checked on 15 November 2026. Codes change and differ between countries, states and towns. Ask your local building department before you build.