BTU calculator
Enter the room size. The calculator finds the cooling capacity of a room air conditioner in ENERGY STAR's sizing table and applies its adjustments for sun, shade, people and a kitchen. It also sizes a mini split and an electric room heater by the makers' rules. Results are in BTU per hour, tons and kilowatts.
How the calculator works
- Floor area. Length × width, or the area you type.
- Room air conditioner. The calculator reads the capacity for the area in ENERGY STAR's table. Then it takes off 10 % for a heavily shaded room or adds 10 % for a very sunny one, adds 600 BTU per hour for each person beyond two, and adds 4,000 BTU per hour for a kitchen.
- Mini split. The area in square feet × 25 BTU per hour, the initial estimate that Carrier and Trane give. The result is the smallest size in Trane's chart that covers it.
- Electric heater. The area in square feet × 10 W for extra heat, or × 15 W where the room has no other heat or is poorly insulated. This is Broan-NuTone's rule.
- Tons and kilowatts. One ton is 12,000 BTU per hour, and 1 BTU per hour is 0.2931 W.
A BTU (British thermal unit) is an amount of heat. Air conditioners and heaters are rated in BTU per hour, written BTU/h. Many labels shorten this to BTU.
Worked example
A living room is 20 × 15 ft (6.10 × 4.57 m). It is very sunny, and four people use it.
| Step | Calculation | Result |
|---|---|---|
| Floor area | 20 ft × 15 ft | 300 sq ft (27.9 m²) |
| From the table | Row "300 up to 350 sq ft" | 8,000 BTU/h |
| Very sunny | 8,000 × 10 % | +800 BTU/h |
| People | (4 − 2) × 600 | +1,200 BTU/h |
| Cooling capacity | 8,000 + 800 + 1,200 | 10,000 BTU/h |
| Tons | 10,000 ÷ 12,000 | 0.83 tons |
| Kilowatts | 10,000 × 0.2931 ÷ 1,000 | 2.93 kW |
The same room with average sun and two people needs 8,000 BTU/h. A mini split for it is 300 × 25 = 7,500 BTU/h by the makers' estimate, so the 9,000 BTU/h size.
Air conditioner size by room size
This is ENERGY STAR's table for room air conditioners: window, portable and through-the-wall units. The capacities are for a ceiling 8 ft (2.44 m) high. A room on the boundary of two rows takes the row that starts there.
| Area to cool | In square meters | Capacity | In kilowatts |
|---|---|---|---|
| 100 up to 150 sq ft | 9.3 up to 13.9 m² | 5,000 BTU/h | 1.47 kW |
| 150 up to 250 sq ft | 13.9 up to 23.2 m² | 6,000 BTU/h | 1.76 kW |
| 250 up to 300 sq ft | 23.2 up to 27.9 m² | 7,000 BTU/h | 2.05 kW |
| 300 up to 350 sq ft | 27.9 up to 32.5 m² | 8,000 BTU/h | 2.34 kW |
| 350 up to 400 sq ft | 32.5 up to 37.2 m² | 9,000 BTU/h | 2.64 kW |
| 400 up to 450 sq ft | 37.2 up to 41.8 m² | 10,000 BTU/h | 2.93 kW |
| 450 up to 550 sq ft | 41.8 up to 51.1 m² | 12,000 BTU/h | 3.52 kW |
| 550 up to 700 sq ft | 51.1 up to 65.0 m² | 14,000 BTU/h | 4.10 kW |
| 700 up to 1,000 sq ft | 65.0 up to 92.9 m² | 18,000 BTU/h | 5.28 kW |
| 1,000 up to 1,200 sq ft | 92.9 up to 111.5 m² | 21,000 BTU/h | 6.15 kW |
| 1,200 up to 1,400 sq ft | 111.5 up to 130.1 m² | 23,000 BTU/h | 6.74 kW |
| 1,400 up to 1,500 sq ft | 130.1 up to 139.4 m² | 24,000 BTU/h | 7.03 kW |
| 1,500 up to 2,000 sq ft | 139.4 up to 185.8 m² | 30,000 BTU/h | 8.79 kW |
| 2,000 up to 2,500 sq ft | 185.8 up to 232.3 m² | 34,000 BTU/h | 9.96 kW |
Adjustments for sun, people and a kitchen
| Condition | Change | Source |
|---|---|---|
| Heavily shaded room | 10 % less | ENERGY STAR |
| Very sunny room | 10 % more | ENERGY STAR |
| More than two people regularly in the room | 600 BTU/h more for each person beyond two | ENERGY STAR |
| Unit in a kitchen | 4,000 BTU/h more | ENERGY STAR |
| Ceiling higher than 8 ft (2.44 m) | More capacity, with no figure given | ENERGY STAR, Carrier, Trane |
ENERGY STAR states that its capacities are for an 8 ft ceiling, and gives no percent for a higher one. Carrier and Trane also say that a ceiling above 8 ft needs more capacity, without a figure. The calculator therefore does not change the result for the ceiling height. For a room with a high ceiling, ask an installer.
Mini split size by area
Carrier estimates a mini split at 25 BTU per hour for each square foot (79 W per m²). Trane gives 12 to 25 BTU per hour for each square foot, and its chart uses 25. Both call it a rough estimate and ask for a load calculation.
| Room, zone or house | In square meters | Mini split size | Tons |
|---|---|---|---|
| Up to 240 sq ft | Up to 22.3 m² | 6,000 BTU/h (1.76 kW) | 0.5 |
| 240 to 360 sq ft | 22.3 to 33.4 m² | 9,000 BTU/h (2.64 kW) | 0.75 |
| 360 to 480 sq ft | 33.4 to 44.6 m² | 12,000 BTU/h (3.52 kW) | 1 |
| 480 to 600 sq ft | 44.6 to 55.7 m² | 15,000 BTU/h (4.40 kW) | 1.25 |
| 600 to 720 sq ft | 55.7 to 66.9 m² | 18,000 BTU/h (5.28 kW) | 1.5 |
| 720 to 960 sq ft | 66.9 to 89.2 m² | 24,000 BTU/h (7.03 kW) | 2 |
| 960 to 1,200 sq ft | 89.2 to 111.5 m² | 30,000 BTU/h (8.79 kW) | 2.5 |
| 1,200 to 1,440 sq ft | 111.5 to 133.8 m² | 36,000 BTU/h (10.55 kW) | 3 |
| 1,440 to 1,920 sq ft | 133.8 to 178.4 m² | 48,000 BTU/h (14.07 kW) | 4 |
| 1,920 to 2,400 sq ft | 178.4 to 223.0 m² | 60,000 BTU/h (17.58 kW) | 5 |
Trane advises that a ductless system is not more than half a ton above the result of a load calculation. In a system with several indoor units, each indoor unit is sized for its room or zone, and the outdoor unit for all of them.
Heating BTU for a room
Broan-NuTone gives a rule for electric room heaters: 10 W for each square foot (108 W per m²) supplies extra heat in most climates. Where the room has no other heat, or is poorly insulated, 15 W for each square foot (161 W per m²) may be needed. In BTU, that is 34 and 51 BTU per hour for each square foot.
| Room | Extra heat | Sole heat source |
|---|---|---|
| 100 sq ft (9.3 m²) | 1,000 W (3,412 BTU/h) | 1,500 W (5,118 BTU/h) |
| 150 sq ft (13.9 m²) | 1,500 W (5,118 BTU/h) | 2,250 W (7,677 BTU/h) |
| 200 sq ft (18.6 m²) | 2,000 W (6,824 BTU/h) | 3,000 W (10,236 BTU/h) |
| 300 sq ft (27.9 m²) | 3,000 W (10,236 BTU/h) | 4,500 W (15,355 BTU/h) |
This rule is for an electric heater in one room. It does not size a furnace, a boiler or a heat pump. The heat that a house loses depends on its climate, insulation, windows and air leaks, and a load calculation finds it.
What a load calculation adds
The tables on this page use the floor area alone. ACCA Manual J is the US standard for the heating and cooling load of a home. It calculates the loads from the building's envelope, its windows, its orientation and the climate. Section M1401.3 of the International Residential Code, as the 2021 Seattle Residential Code prints it, requires that heating and cooling equipment is sized with ACCA Manual S, or another approved method, from loads calculated with ACCA Manual J, or another approved method.
Use this calculator for a window, portable or through-the-wall unit in one room, and for a first idea of a mini split or a room heater. For central air, a furnace, a heat pump or a mini split system for a whole house, ask a contractor for a load calculation and ask to see its result.
Questions
What size air conditioner do I need for a 12 × 12 room?
A 12 × 12 ft room is 144 sq ft (13.4 m²). ENERGY STAR's table gives 5,000 BTU per hour for 100 up to 150 sq ft. Add 4,000 BTU per hour if the room is a kitchen.
How many BTU do I need per square foot?
ENERGY STAR's table works out at 20 to 28 BTU per hour for each square foot in rooms of 250 to 700 sq ft, more in smaller rooms and less in larger ones. Carrier and Trane take 25 BTU per hour for each square foot for a first estimate of a mini split.
How many BTU do I need for 500 square feet?
12,000 BTU per hour, which is 1 ton, for a room air conditioner by ENERGY STAR's table. A mini split by Trane's chart is 15,000 BTU per hour.
How many BTU do I need for 1,000 square feet?
21,000 BTU per hour for a room air conditioner by ENERGY STAR's table. A mini split by Trane's chart is 30,000 BTU per hour, which is 2.5 tons. For a space of this size, ask for a load calculation.
How many BTU are in a ton?
One ton of cooling is 12,000 BTU per hour, or 3.517 kW. An 18,000 BTU per hour unit is 1.5 tons and a 24,000 BTU per hour unit is 2 tons.
How do I convert BTU to kW?
Multiply BTU per hour by 0.2931 and divide by 1,000. A 12,000 BTU per hour unit cools with 3.52 kW. This is the heat that the unit moves, not the electricity that it uses.
Is a bigger air conditioner better?
No. ENERGY STAR states that a unit that is too large cools the room before it removes the humidity, so the air feels damp and clammy. It also costs more and wastes energy.
How many BTU do I need to heat a room?
For an electric room heater, Broan-NuTone gives 10 W for each square foot as extra heat and 15 W as the sole heat source. That is 34 and 51 BTU per hour for each square foot: a 150 sq ft room takes 1,500 W (5,118 BTU per hour) of extra heat.
Sources
- ENERGY STAR: Room air conditioners, "Properly sized room air conditioners"
- Carrier: Calculating what size mini split I need
- Trane: What size mini split do I need?
- Broan-NuTone: How do I determine the appropriate size heater for my room?
- ACCA: Manual J, residential load calculation
- City of Seattle: 2021 Seattle Residential Code, chapter 14, with section M1401.3 of the International Residential Code (PDF)
- NIST: Guide for the use of the SI, appendix B.9, conversion factors for power
- Square footage calculator
- How to measure a room
- Ceiling height: standard, minimum and basement ceiling heights
Checked on 15 November 2026. The tables estimate from the floor area alone. For a system that serves a whole house, ask a contractor for a load calculation.